Non-Standard Single Armour Wires
CMP also provide alternate cable glands for when the cable armour wires are outside of the standard range.
This is especially true for single wire armour cables (SWA), where a change in the wire size can affect the cable gland selection.
IEC 605021 outlines the nominal wire sizes that should be used in relation to the cable bedding diameter.
There are two possible, and different outcomes, when there is a variation in the armour wire thickness, one being a different nominal size of wire is used in the cable manufacture, and another being the nominal wire thickness being over or under size. Details of these alternatives are included in the table below.
Cable Gland Size | Example Ordering Reference* | Armour Range Standard W Cone '1RA' Cable | Armour Range Standard X Cone '1RA' | Armour Range Undersize '1RE' | Armour Range Oversize '1RB' |
||||
Min | Max | Min | Max | Min | Max | Min | Max | ||
20S16 | 20S16T3CDS1RA | 0.8 | 1.25 | 0.3 | 1.0 | 0.7 | 1.15 | 1.15 | 1.6 |
20S | 20ST3CDS1RA | 0.8 | 1.25 | 0.3 | 1.0 | 0.7 | 1.15 | 1.15 | 1.6 |
20 | 20T3CDS1RA | 0.8 | 1.25 | 0.4 | 1.0 | 0.7 | 1.15 | 1.15 | 1.6 |
25S | 25ST3CDS1RA | 1.25 | 1.6 | 0.4 | 1.2 | 0.77 | 1.22 | 1.63 | 2.13 |
25 | 25T3CDS1RA | 1.25 | 1.6 | 0.4 | 1.2 | 0.77 | 1.22 | 1.63 | 2.13 |
32 | 32T3CDS1RA | 1.6 | 2.0 | 0.4 | 1.2 | 1.12 | 1.62 | 2.0 | 2.6 |
40 | 40T3CDS1RA | 1.6 | 2.0 | 0.4 | 1.6 | 1.12 | 1.62 | 2.0 | 2.6 |
50S | 50ST3CDS1RA | 2.0 | 2.5 | 0.4 | 1.6 | 1.33 | 2.0 | 2.4 | 3.1 |
50 | 50T3CDS1RA | 2.0 | 2.5 | 0.6 | 1.6 | 1.33 | 2.0 | 2.4 | 3.1 |
63S | 63ST3CDS1RA | 2.0 | 2.5 | 0.6 | 1.6 | 1.33 | 2.0 | 2.4 | 3.1 |
63 | 63T3CDS1RA | 2.0 | 2.5 | 0.6 | 1.6 | 1.33 | 2.0 | 2.4 | 3.1 |
75S | 75ST3CDS1RA | 2.0 | 2.5 | 0.6 | 1.6 | 1.33 | 2.0 | 2.4 | 3.1 |
75 | 75T3CDS1RA | 2.5 | 3.0 | 0.6 | 1.6 | 1.83 | 2.53 | 2.8 | 3.5 |
90 | 90T3CDS1RA | 3.15 | 4.0 | 0.8 | 1.6 | 2.0 | 3.2 | 3.6 | 4.3 |
100 | 100T3CDS1RA | 3.15 | 4.0 | 0.8 | 1.6 | 2.0 | 3.2 | 3.6 | 4.3 |
115 | 115T3CDS1RA | 3.15 | 4.0 | 0.8 | 1.6 | 2.0 | 3.2 | 3.6 | 4.3 |
130 | 130T3CDS1RA | 3.15 | 4.0 | 0.8 | 1.6 | 2.0 | 3.2 | 3.6 | 4.3 |
All dimension shown are in millimetres unless otherwise stated | |||||||||
*Example ordering reference, T3CDS reference should be replaced by ordered Cable Gland. 1RA suffix should be replaced with reference depending on armour size needed |
Cable Gland Examples | Armour Range Standard W Cone 1RA | Armour Range Standard X Cone 1RA | Armour Range Undersize 1RE | Armour Range Oversize 1RB |
CW / CX | 20CW1RA | 20CX1RA | 20CW1RE | 20CW1RB |
E1U | 20E1U1RA | 20E1U1RA | 20E1U1RE | 20E1U1RB |
E1FW / E1FX | 20E1FW1RA | 20E1FX1RA | 20E1FW1RE | 20E1FW1RB |
PX2K | 20PX2K1RA | 20PX2K1RA | 20PX2K1RE | 20PX2K1RB |
PX2KREX | 20PX2KREX1RA | 20PX2KREX1RA | 20PX2KREX1RE | 20PX2KREX1RB |
T3CDS | 20T3CDS1RA | 20T3CDS1RA | 20T3CDS1RE | 20T3CDS1RB |
Brass M20 shown as example |