PXSS2K/M | Ex eb, Ex db | Explosive Atmosphere Cable Gland For all types of Unarmoured Cables

Mining, Internationally Approved, Explosive Atmosphere Barrier Cable Gland

• Displacement type environmental seal
• Compound barrier type flameproof seal
• Designed to prevent Coldflow
• -60°C to +85°C
• Permitted in Zone 1
• Internationally marked, IECEx & ATEX
• Once any cable inner sheath/bedding has been removed, the RapidEx liquid resin barrier seals directly around the internal cable cores, completely eliminating any risk of coldflow on all cable types

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
ATEX Certificate CML 18ATEX1325X
Code of Protection IM2 Ex db I Mb, Ex eb I Mb
Compliance Standards EN 60079-0,1,7
IECEx Certificate IECEx CML 18.0182X
UkrSEPRO CU 19.0371X
Code of Protection Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7
CCOE / PESO (India) Certificate P444949
Ingress Protection Rating ** IP66, IP67 & IP68**
Deluge Protection Compliance DTS01:91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
Cable Type Unarmoured
Sealing Technique CMP Unique Displacement Seal Concept
Sealing Area(s) Inner Compound Barrier & Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners

* Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Cable Gland SizeMinimum Thread Length "E"Entry Thread "C"Maximum Diameter Over Conductors "A"Maximum Number of CoresCable Bedding Diameter "G"Overall
Cable
Diameter
'B'
Across
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
Option
DiameterCoresMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S0.59M200.50110.460.240.461.181.302.0920SPXSS2K1RA/MPVC067.05
200.59M200.50110.510.260.551.181.302.1320PXSS2K1RA/MPVC067.05
250.59M250.69210.700.440.791.421.562.3625PXSS2K1RA/MPVC0911.64
320.59M320.93380.940.671.041.611.782.4132PXSS2K1RA/MPVC1020.81
400.59M401.18591.190.871.261.972.172.4640PXSS2K1RA/MPVC1319.75
50S0.59M501.44891.451.161.502.172.382.5750SPXSS2K1RA/MPVC1523.28
500.59M501.61891.631.401.732.362.602.6650PXSS2K1RA/MPVC1825.75
63S0.59M631.891151.911.581.962.763.032.8063SPXSS2K1RA/MPVC2137.74
630.59M632.111152.131.862.202.953.252.7763PXSS2K1RA/MPVC2337.39
75S0.59M752.351402.372.082.443.153.462.9675SPXSS2K1RA/MPVC2545.86
750.59M752.531402.532.332.673.353.682.9575PXSS2K1RA/MPVC2745.86
Dimensions displayed in inches unless otherwise stated
Cable Gland SizeMinimum Thread Length "E"Entry Thread "C"Maximum Diameter Over Conductors "A"Maximum Number of CoresCable Bedding Diameter "G"Overall
Cable
Diameter
'B'
Across
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
Option
DiameterCoresMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S15.0M2012.61111.76.111.730.033.053.120SPXSS2K1RA/MPVC060.20
2015.0M2012.61112.96.514.030.033.054.220PXSS2K1RA/MPVC060.20
2515.0M2517.52117.911.120.036.039.660.025PXSS2K1RA/MPVC090.33
3215.0M3223.63823.917.026.341.045.161.132PXSS2K1RA/MPVC100.59
4015.0M4030.05930.322.032.150.055.062.440PXSS2K1RA/MPVC130.56
50S15.0M5036.68936.929.538.255.060.565.250SPXSS2K1RA/MPVC150.66
5015.0M5041.08941.335.644.060.066.067.650PXSS2K1RA/MPVC180.73
63S15.0M6347.911548.440.149.970.077.071.163SPXSS2K1RA/MPVC211.07
6315.0M6353.711554.047.255.975.082.570.463PXSS2K1RA/MPVC231.06
75S15.0M7559.814060.252.861.980.088.075.375SPXSS2K1RA/MPVC251.30
7515.0M7564.314064.259.167.985.093.574.975PXSS2K1RA/MPVC271.30
Dimensions displayed in millimeters unless otherwise stated

Technical Illustration