PX2KPB | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Barrier Cable Gland For all types of Lead Sheathed Armoured cables

Internationally Approved, Explosive Atmosphere Barrier Cable Gland

• Effectively earths / grounds lead sheathed cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Internationally marked, IECEx & ATEX
• EMC tested
• Compound barrier seals around internal cable cores after removing any inner cable sheath/bedding; completely eliminating any risk of coldflow

For under / oversized armour wires click here

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications* Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate CML 18ATEX1325X, CML 18ATEX4317X
UKEX Certificate CML 21UKEX1214X, CML 21UKEX4215X
Code of Protection II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da,
II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb
Compliance Standards EN 60079-0,1,7,15,31
IECEx Certificate IECEx CML 18.0182X
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
CCOE / PESO (India) Certificate Ex d: P548696, Ex e: P533772 Ex nR: P548695
CCC Certificate 2020322313003190
INMETRO Approval TÜV 12.2073X
RETIE Approval 03866
UkrSEPRO CU 19.0371X
Marine Approvals LRS: 01/00172, DNV: TAE000000Y, ABS: 20-LD1948801-PDA
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer / Epoxy Barrier Compound
Cable Type Lead Sheathed & Single Wire Armour (LC/SWA), Lead Sheathed & Aluminium Wire Armour (LC/
AWA), Lead Sheathed & Wire Braid Armour (LC/SWB), Lead Sheathed & Pliable Wire Armour (LC/
PWA), Lead Sheathed & Steel Tape Armour (LC/STA), Lead Sheathed & Aluminium Strip Armour (LC/ASA)
Armour Clamping Detachable Compound Tube / Cone & AnyWay Universal Clamping Ring
Sealing Technique Unique CMP ‘LRS’ Outer Seal (Load Retention Seal)
Sealing Area(s) Inner Compound Barrier & Outer Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners
SANS MS-XPL21962 21.0305X
ECAS Certificate 24-03-106290/E24-03-110155/NB0007

Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors
'A'
Lead Sheath Diameter 'G'Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Ozs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.59½'0.78¾'210.310.120.310.240.520.010.040.030.051.201.322.4420S16PX2KPB1RAPVC068.82
20SM200.59½'0.78¾'210.430.240.430.370.630.010.040.030.051.201.322.4420SPX2KPB1RAPVC068.11
20M200.59½'0.78¾'210.500.260.530.490.820.020.040.030.051.201.322.4820PX2KPB1RAPVC068.47
25SM250.59¾'0.801'300.690.440.760.550.870.020.050.050.061.481.632.7425SPX2KPB1RAPVC0913.05
25M250.59¾'0.801'300.690.440.760.721.030.020.050.050.061.481.632.7425PX2KPB1RAPVC0913.05
32M320.591'0.981 ¼'380.930.671.000.931.330.020.050.060.081.811.992.9532PX2KPB1RAPVC1120.11
40M400.591 ¼'1.011 ½'591.180.871.231.101.590.020.060.060.082.172.382.9540PX2KPB1RAPVC1528.22
50SM500.591 ½'1.032'891.441.161.461.391.840.020.060.080.102.362.603.0350SPX2KPB1RAPVC1831.75
50M500.592'1.062 ½'1151.611.401.681.592.090.020.060.080.102.763.043.0350PX2KPB1RAPVC2141.98
63SM630.592'1.062 ½'1151.891.581.911.802.340.020.060.080.102.953.253.1463SPX2KPB1RAPVC2349.74
63M630.592 ½'1.573'1152.111.862.132.152.590.020.060.080.103.153.463.1663PX2KPB1RAPVC2550.79
75SM750.592 ½'1.573'1402.362.082.372.322.830.020.060.080.103.543.903.4275SPX2KPB1RAPVC2875.13
75M750.593'1.633 ½'1402.532.332.572.633.090.020.060.100.123.944.333.4875PX2KPB1RAPVC3090.65
90M900.793 ½'1.694'1402.962.623.043.003.560.030.060.120.164.534.984.0290PX2KPB1RAPVC32132.28
100M1000.794'1.735'2003.372.993.473.393.990.030.060.120.165.005.504.49100PX2KPB1RALSF33171.78
Dimensions displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Number of CoresDiameter Over Conductors
'A'
Lead Sheath Diameter 'G'Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2015.0½'19.9¾'217.83.17.86.113.10.31.00.81.2530.533.662.020S16PX2KPB1RAPVC060.25
20SM2015.0½'19.9¾'2111.06.111.09.515.90.31.00.81.2530.533.662.020SPX2KPB1RAPVC060.23
20M2015.0½'19.9¾'2112.66.513.412.520.90.41.00.81.2530.533.663.020PX2KPB1RAPVC060.24
25SM2515.0¾'20.21'3017.511.119.314.022.00.41.21.251.637.541.369.525SPX2KPB1RAPVC090.37
25M2515.0¾'20.21'3017.511.119.318.226.20.41.21.251.637.541.369.525PX2KPB1RAPVC090.37
32M3215.01'25.01 ¼'3823.617.025.523.733.90.41.21.62.046.050.675.032PX2KPB1RAPVC110.57
40M4015.01 ¼'25.61 ½'5930.022.031.227.940.40.41.61.62.055.060.575.040PX2KPB1RAPVC150.80
50SM5015.01 ½'26.12'8936.629.537.235.246.70.41.62.02.560.066.077.050SPX2KPB1RAPVC180.90
50M5015.02'26.92 ½'11541.035.642.640.453.00.61.62.02.570.177.177.050PX2KPB1RAPVC211.19
63SM6315.02'26.92 ½'11547.940.148.545.659.40.61.62.02.575.082.579.763SPX2KPB1RAPVC231.41
63M6315.02 ½'39.93'11553.747.254.254.665.80.61.62.02.580.088.080.363PX2KPB1RAPVC251.44
75SM7515.02 ½'39.93'14059.952.860.259.072.00.61.62.02.590.099.086.875SPX2KPB1RAPVC282.13
75M7515.03'41.53 ½'14064.259.165.266.778.40.61.62.53.0100.0110.088.375PX2KPB1RAPVC302.57
90M9020.03 ½'42.84'14075.366.677.176.290.30.81.63.154.0115.0126.5102.190PX2KPB1RAPVC323.75
100M10020.04'44.05'20085.676.088.186.1101.40.81.63.154.0127.0139.7114.0100PX2KPB1RALSF334.87
Dimensions displayed in millimeters unless otherwise stated

Technical Illustration

Additional Information

Combating Galvanic Corrosion at CMP

The type and thickness of nickel coatings applied to brass cable glands varies significantly around the world, and many of the solutions adopted are inherently porous, meaning that they are unable to provide complete protection against chemical attack, corrosion, or material break-down. There are typically two types of nickel plating in common use, these being electro nickel plating and electro-less nickel plating.

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Sign up now