Globally Approved, Explosive Atmosphere Cable Gland
• Stainless steel compact design
• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system(CDS)
• Metal-to-metal installation regardless of cable bedding diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX & cCSAus
• Superior EMC performance
Patents granted: GB 1077517
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class D |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
Electrical Classifications* | Category B (Category A when used with braid, tape or pliable wire armour cables) |
ATEX Certificate | CML 18ATEX1326X CML 18ATEX4318X |
UKEX Certificate | "CML 21UKEX1258X,CML 21UKEX4259X" |
Code of Protection | II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da, II 3G Ex nR IIC Gc, I M2, Ex db I Mb, Ex eb I Mb |
Compliance Standards | EN60079-0,1,7,15,31 |
IECEx Certificate | IECEx CML 18.0183X |
Code of Protection | Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb |
Compliance Standards | IEC 60079-0,1,7,15,31 |
cCSAus Certificate (20s16 - 90) | 1310517 |
CSAus Code of Protection | Class II, Div 2, Groups E,F and G, Class III, Enclosure Type 4X, Oil Res II Class I, Zone 1, AEx e II, AEx nR II |
cCSA Code of Protection | Class I, Div 2, Groups A,B,C and D, Class II, Div 2, Groups E,F and G, Class III, Enclosure Type 3, 4 and 4X, Ex d IIC, Ex e IIC, Ex nR II |
Compliance Standards | CAN/CSA-C22.2 No 0, 18, 25, 30, 94, 174, CAN/CSA-E60079-0, 1, 7, ANSI/UL 514B Ed 5, ANSI/UL 50 Ed 11, ANSI/UL 2225 Ed 4, UL60079-0, 1, 7 |
EAC Certificate | C-GB.A07.B.02514/20 |
CCC Certificate | 2020322313002527 |
CCOE / PESO (India) Certificate | Ex d: P548696, Ex e: P533772 Ex nR: P548695 |
INMETRO Approval | TÜV 11.0374X |
KCS Certificate | Size 16 - 32 Size 40 - 63 Size 75S - 115 Size 130 |
UkrSEPRO | CU 19.0371X |
Marine Approvals | LRS: 01/00172, DNV: TAE00000Y, ABS: 20-LD1948801-PDA, BV: 43180/A1BV |
Ingress Protection Rating ** | IP66, IP67 & IP68 |
Deluge Protection Compliance | DTS01 : 91 |
Cable Gland Material | Stainless Steel |
Seal Material | CMP SOLO LSF Halogen Free Thermoset Elastomer |
Cable Type | Single Wire Armour (SWA), Aluminium Wire Armour (AWA), Pliable Wire Armour (PWA), Steel Tape Armour (STA), Aluminium Strip Armour (ASA), Screened Flexible (EMC) Wire Braid (e.g. CY/SY), Wire Braid Armour (e.g SWB) |
Armour Clamping | Reversible Armour Cone & AnyWay Universal Clamping Ring |
Sealing Technique | Inner Bedding Sealing Ring: Compensating Displacement Seal (CDS), Outer Sheath Sealing Ring : Load Retention Seal (LRS) |
Sealing Area(s) | Cable Inner Bedding & Outer Cable Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners, Armour Former Tool |
ECAS Certificate | 24-03-106290/E24-03-110155/NB0007 |
Note : *Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter 'A' | Overall Cable Diameter 'B' | Armour Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (Stainless Steel Metric) | Shroud | Cable Gland Weight (Ozs) |
|||||||||||
Standard | Option | Grooved Cone (X) | Stepped Cone (W) | ||||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Min | Max | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 0.59 | ½' | 0.78 | ¾" | 0.12 | 0.34 | 0.24 | 0.52 | 0.01 | 0.04 | 0.03 | 0.05 | 0.94 | 1.04 | 2.26 | 20S16 | TE1FU | 1RA4 | PVC04 | 5.29 |
20S | M20 | 0.59 | ½' | 0.78 | ¾" | 0.24 | 0.46 | 0.37 | 0.63 | 0.01 | 0.04 | 0.03 | 0.05 | 0.94 | 1.04 | 2.26 | 20S | TE1FU | 1RA4 | PVC04 | 5.29 |
20 | M20 | 0.59 | ½' | 0.78 | ¾" | 0.26 | 0.55 | 0.49 | 0.82 | 0.02 | 0.04 | 0.03 | 0.05 | 1.20 | 1.32 | 2.41 | 20 | TE1FU | 1RA4 | PVC06 | 8.11 |
25S | M25 | 0.59 | ¾' | 0.80 | 1" | 0.44 | 0.78 | 0.55 | 0.87 | 0.02 | 0.05 | 0.05 | 0.06 | 1.48 | 1.63 | 2.91 | 25S | TE1FU | 1RA4 | PVC09 | 11.99 |
25 | M25 | 0.59 | ¾' | 0.80 | 1" | 0.44 | 0.78 | 0.72 | 1.03 | 0.02 | 0.05 | 0.05 | 0.06 | 1.48 | 1.63 | 2.91 | 25 | TE1FU | 1RA4 | PVC09 | 11.99 |
32 | M32 | 0.59 | 1' | 0.98 | 1 ¼" | 0.67 | 1.03 | 0.93 | 1.33 | 0.02 | 0.05 | 0.06 | 0.08 | 1.81 | 1.99 | 3.08 | 32 | TE1FU | 1RA4 | PVC11 | 19.40 |
40 | M40 | 0.59 | 1 ¼' | 1.01 | 1 ½" | 0.87 | 1.26 | 1.10 | 1.59 | 0.02 | 0.06 | 0.06 | 0.08 | 2.17 | 2.38 | 3.21 | 40 | TE1FU | 1RA4 | PVC15 | 27.87 |
50S | M50 | 0.59 | 1 ½' | 1.03 | 2" | 1.16 | 1.50 | 1.39 | 1.84 | 0.02 | 0.06 | 0.08 | 0.10 | 2.36 | 2.60 | 3.47 | 50S | TE1FU | 1RA4 | PVC18 | 35.27 |
50 | M50 | 0.59 | 2' | 1.06 | 2 ½" | 1.40 | 1.73 | 1.59 | 2.09 | 0.02 | 0.06 | 0.08 | 0.10 | 2.76 | 3.04 | 3.59 | 50 | TE1FU | 1RA4 | PVC21 | 48.33 |
63S | M63 | 0.59 | 2' | 1.06 | 2 ½" | 1.58 | 1.96 | 1.80 | 2.34 | 0.02 | 0.06 | 0.08 | 0.10 | 2.95 | 3.24 | 3.56 | 63S | TE1FU | 1RA4 | PVC23 | 52.91 |
63 | M63 | 0.59 | 2 ½' | 1.57 | 3" | 1.86 | 2.20 | 2.15 | 2.59 | 0.02 | 0.06 | 0.08 | 0.10 | 3.15 | 3.46 | 3.56 | 63 | TE1FU | 1RA4 | PVC25 | 55.03 |
75S | M75 | 0.59 | 2 ½' | 1.57 | 3" | 2.08 | 2.44 | 2.32 | 2.83 | 0.02 | 0.06 | 0.08 | 0.10 | 3.54 | 3.90 | 4.12 | 75S | TE1FU | 1RA4 | PVC28 | 86.42 |
75 | M75 | 0.59 | 3' | 1.63 | 3 ½" | 2.33 | 2.67 | 2.63 | 3.09 | 0.02 | 0.06 | 0.10 | 0.12 | 3.94 | 4.33 | 4.36 | 75 | TE1FU | 1RA4 | PVC30 | 111.11 |
90 | M90 | 0.94 | 3 ½' | 1.69 | 4" | 2.62 | 3.09 | 3.00 | 3.56 | 0.03 | 0.06 | 0.12 | 0.16 | 4.53 | 4.98 | 5.33 | 90 | TE1FU | 1RA4 | PVC32 | 162.97 |
100 | M100 | 0.94 | 3 ½' | 1.69 | 4" | 2.99 | 3.58 | 3.39 | 3.99 | 0.03 | 0.06 | 0.12 | 0.16 | 5.00 | 5.50 | 4.99 | 100 | TE1FU | 1RA4 | LSF33 | 174.61 |
115 | M115 | 0.94 | 4" | 1.73 | 5" | 3.39 | 3.85 | 4.00 | 4.34 | 0.03 | 0.06 | 0.12 | 0.16 | 5.43 | 5.98 | 6.20 | 115 | TE1FU | 1RA4 | LSF34 | 268.08 |
130 | M130 | 0.94 | 5" | 1.84 | - | 3.82 | 4.52 | 4.34 | 4.85 | 0.03 | 0.06 | 0.12 | 0.16 | 6.18 | 6.80 | 6.48 | 130 | TE1FU | 1RA4 | LSF35 | 307.94 |
Dimensions displayed in inches unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Cable Bedding Diameter 'A' | Overall Cable Diameter 'B' | Armour Range | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (Stainless Steel Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||||||||
Standard | Option | Grooved Cone (X) | Stepped Cone (W) | ||||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Min | Max | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 15.0 | ½' | 19.9 | ¾" | 3.1 | 8.6 | 6.1 | 13.1 | 0.3 | 1.0 | 0.8 | 1.25 | 24.0 | 26.4 | 57.3 | 20S16 | TE1FU | 1RA4 | PVC04 | 0.15 |
20S | M20 | 15.0 | ½' | 19.9 | ¾" | 6.1 | 11.6 | 9.5 | 15.9 | 0.3 | 1.0 | 0.8 | 1.25 | 24.0 | 26.4 | 57.3 | 20S | TE1FU | 1RA4 | PVC04 | 0.15 |
20 | M20 | 15.0 | ½' | 19.9 | ¾" | 6.5 | 13.9 | 12.5 | 20.9 | 0.4 | 1.0 | 0.8 | 1.25 | 30.5 | 33.6 | 61.2 | 20 | TE1FU | 1RA4 | PVC06 | 0.23 |
25S | M25 | 15.0 | ¾' | 20.2 | 1" | 11.1 | 19.9 | 14.0 | 22.0 | 0.4 | 1.2 | 1.25 | 1.6 | 37.5 | 41.3 | 74.0 | 25S | TE1FU | 1RA4 | PVC09 | 0.34 |
25 | M25 | 15.0 | ¾' | 20.2 | 1" | 11.1 | 19.9 | 18.2 | 26.2 | 0.4 | 1.2 | 1.25 | 1.6 | 37.5 | 41.3 | 74.0 | 25 | TE1FU | 1RA4 | PVC09 | 0.34 |
32 | M32 | 15.0 | 1' | 25.0 | 1 ¼" | 17.0 | 26.2 | 23.7 | 33.9 | 0.4 | 1.2 | 1.6 | 2.0 | 46.0 | 50.6 | 78.2 | 32 | TE1FU | 1RA4 | PVC11 | 0.55 |
40 | M40 | 15.0 | 1 ¼' | 25.6 | 1 ½" | 22.0 | 32.1 | 27.9 | 40.4 | 0.4 | 1.6 | 1.6 | 2.0 | 55.0 | 60.5 | 81.6 | 40 | TE1FU | 1RA4 | PVC15 | 0.79 |
50S | M50 | 15.0 | 1 ½' | 26.1 | 2" | 29.5 | 38.1 | 35.2 | 46.7 | 0.4 | 1.6 | 2.0 | 2.5 | 60.0 | 66.0 | 88.1 | 50S | TE1FU | 1RA4 | PVC18 | 1.00 |
50 | M50 | 15.0 | 2' | 26.9 | 2 ½" | 35.6 | 44.0 | 40.4 | 53.0 | 0.6 | 1.6 | 2.0 | 2.5 | 70.1 | 77.1 | 91.2 | 50 | TE1FU | 1RA4 | PVC21 | 1.37 |
63S | M63 | 15.0 | 2' | 26.9 | 2 ½" | 40.1 | 49.9 | 45.6 | 59.4 | 0.6 | 1.6 | 2.0 | 2.5 | 75.0 | 82.4 | 90.5 | 63S | TE1FU | 1RA4 | PVC23 | 1.50 |
63 | M63 | 15.0 | 2 ½' | 39.9 | 3" | 47.2 | 55.9 | 54.6 | 65.8 | 0.6 | 1.6 | 2.0 | 2.5 | 80.0 | 88.0 | 90.3 | 63 | TE1FU | 1RA4 | PVC25 | 1.56 |
75S | M75 | 15.0 | 2 ½' | 39.9 | 3" | 52.8 | 61.9 | 59.0 | 72.0 | 0.6 | 1.6 | 2.0 | 2.5 | 90.0 | 99.0 | 104.7 | 75S | TE1FU | 1RA4 | PVC28 | 2.45 |
75 | M75 | 15.0 | 3' | 41.5 | 3 ½" | 59.1 | 67.9 | 66.7 | 78.4 | 0.6 | 1.6 | 2.5 | 3.0 | 100.0 | 110.0 | 110.8 | 75 | TE1FU | 1RA4 | PVC30 | 3.15 |
90 | M90 | 24.0 | 3 ½' | 42.8 | 4" | 66.6 | 78.6 | 76.2 | 90.3 | 0.8 | 1.6 | 3.15 | 4.0 | 115.0 | 126.5 | 135.5 | 90 | TE1FU | 1RA4 | PVC32 | 4.62 |
100 | M100 | 24.0 | 3 ½' | 42.8 | 4" | 76.0 | 90.9 | 86.1 | 101.4 | 0.8 | 1.6 | 3.15 | 4.0 | 127.0 | 139.7 | 126.8 | 100 | TE1FU | 1RA4 | LSF33 | 4.95 |
115 | M115 | 24.0 | 4" | 44.0 | 5" | 86.0 | 97.9 | 101.5 | 110.2 | 0.8 | 1.6 | 3.15 | 4.0 | 138.0 | 151.8 | 157.5 | 115 | TE1FU | 1RA4 | LSF34 | 7.60 |
130 | M130 | 24.0 | 5" | 46.8 | - | 97.0 | 114.9 | 110.2 | 123.2 | 0.8 | 1.6 | 3.15 | 4.0 | 157.0 | 172.7 | 164.5 | 130 | TE1FU | 1RA4 | LSF35 | 8.73 |
Dimensions displayed in millimeters unless otherwise stated |
Deluge Protection Specification DTS 01:91
The DTS:01 Test Specification was developed by Shell UK in conjunction with ERA Technology, based in Leatherhead, Surrey. Since its inception in 1991 it has been widely accepted by all major offshore operating companies as the standard to meet with respect to deluge protection.
Read moreExplosion Protected Equipment
For equipment which is intended to be used in explosive atmospheres, a number of standard methods of protection against ignition have been established. These have been adopted into construction standards and codes, which allow manufacturers to make equipment of a uniform type and have this equipment tested and certified for compliance with the relevant standards.
Read moreDust Ignition Prevention
Combustible dust can be ignited by electrical equipment in several ways, for example by: - Surfaces of the equipment that are above the minimum ignition temperature of the dust concerned. - The temperature at which a type of dust ignites is a function of the properties of the dust;
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now