- SS2KPB | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Cable Gland
- Ex nR
- Ex ta
SS2KPB | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Lead Sheathed Unarmoured Cables
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
Double Seal, Internationally Approved, Explosive Atmosphere Cable Gland
• Effectively earths / grounds lead sheathed cables
• Direct & remote installation
• Superior levels of cable retention
• Displacement type flameproof seals
• Designed to prevent Coldflow
• Secure against self-loosening
• -60°C to +130°C
• Internationally marked, IECEx & ATEX
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class B |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
ATEX Certificate | CML 18ATEX1322X, CML 18ATEX4314X |
UKEX Certificate | "CML 21UKEX1256X,CML 21UKEX4257X" |
Code of Protection | II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da II 3G Ex nR IIC Gc, IM2 Ex db I Mb, Ex eb I Mb |
Compliance Standards | EN 60079-0,1,7,15,31 |
IECEx Certificate | IECEx CML 18.0178X |
Code of Protection | Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb |
Compliance Standards | IEC 60079-0,1,7,15,31 |
EAC Certificate | C-GB.A07.B.04596/22 |
UkrSEPRO | CU 19.0371X |
CCC Certificate | 2020322313002869 |
CCOE / PESO (India) Certificate | Ex d: P548696, Ex e: P533772 Ex nR: P548695 |
INMETRO Approval | TÜV 12.0879X |
RETIE Approval | 03866 |
Marine Approvals | LRS: 01/00172, DNV: TAE00000Y, ABS: 20-LD1948801-PDA, BV: 43180/A1BV |
SANS | MS-XPL21804 21.0007X |
Ingress Protection Rating ** | IP66, IP67 & IP68 |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium |
Seal Material | CMP SOLO LSF Halogen Free Thermoset Elastomer |
Cable Type | Unarmoured & Lead Sheathed, Lead Covered |
Sealing Technique | CMP Unique Displacement Seal Concept |
Sealing Area(s) | Cable Inner Lead Sheath or Lead Covering and Cable Outer Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners |
ECAS Certificate | 24-03-106290/E24-03-110155/NB0007 |
Note : * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request
Certificates
Product Selection Table
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Diameter over Lead Sheath 'A' | Overall Cable Diameter 'B' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
||||||||
Standard | Option | ||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 0.59 | ½' | 0.78 | ¾" | 0.13 | 0.31 | 0.13 | 0.34 | 0.94 | 1.04 | 1.95 | 20S16 | SS2KPB | 1RA | PVC04 | 4.94 |
20S | M20 | 0.59 | ½' | 0.78 | ¾" | 0.24 | 0.43 | 0.24 | 0.46 | 0.94 | 1.04 | 1.95 | 20S | SS2KPB | 1RA | PVC04 | 4.59 |
20 | M20 | 0.59 | ½' | 0.78 | ¾" | 0.26 | 0.53 | 0.26 | 0.55 | 1.06 | 1.17 | 2.15 | 20 | SS2KPB | 1RA | PVC05 | 5.64 |
25 | M25 | 0.59 | ¾' | 0.80 | 1" | 0.44 | 0.76 | 0.44 | 0.79 | 1.42 | 1.56 | 2.62 | 25 | SS2KPB | 1RA | PVC09 | 10.58 |
32 | M32 | 0.59 | 1' | 0.98 | 1 ¼" | 0.67 | 1.00 | 0.67 | 1.04 | 1.61 | 1.78 | 2.66 | 32 | SS2KPB | 1RA | PVC10 | 12.70 |
40 | M40 | 0.59 | 1 ¼' | 1.01 | 1 ½" | 0.93 | 1.23 | 0.93 | 1.26 | 1.97 | 2.17 | 2.78 | 40 | SS2KPB | 1RA | PVC13 | 17.99 |
50S | M50 | 0.59 | 1 ½' | 1.03 | 2" | 1.22 | 1.46 | 1.22 | 1.50 | 2.17 | 2.38 | 2.58 | 50S | SS2KPB | 1RA | PVC15 | 20.11 |
50 | M50 | 0.59 | 2' | 1.06 | 2 ½" | 1.40 | 1.68 | 1.40 | 1.73 | 2.36 | 2.60 | 2.78 | 50 | SS2KPB | 1RA | PVC18 | 21.16 |
63S | M63 | 0.59 | 2' | 1.06 | 2 ½" | 1.63 | 1.91 | 1.63 | 1.96 | 2.78 | 3.06 | 2.78 | 63S | SS2KPB | 1RA | PVC21 | 31.75 |
63 | M63 | 0.59 | 2 ½' | 1.57 | 3" | 1.86 | 2.13 | 1.86 | 2.20 | 2.95 | 3.25 | 2.81 | 63 | SS2KPB | 1RA | PVC23 | 30.34 |
75S | M75 | 0.59 | 2 ½' | 1.57 | 3" | 2.13 | 2.37 | 2.13 | 2.44 | 3.15 | 3.46 | 2.78 | 75S | SS2KPB | 1RA | PVC25 | 36.33 |
75 | M75 | 0.59 | 3' | 1.63 | 3 ½" | 2.41 | 2.57 | 2.41 | 2.67 | 3.31 | 3.64 | 2.97 | 75 | SS2KPB | 1RA | PVC26 | 35.27 |
90 | M90 | 0.94 | 3 ½' | 1.69 | 4" | 2.62 | 3.04 | 2.62 | 3.13 | 4.25 | 4.68 | 4.47 | 90 | SS2KPB | 1RA | PVC31 | 106.17 |
100 | M100 | 0.94 | 3 ½' | 1.69 | 4" | 2.99 | 3.47 | 2.99 | 3.58 | 4.84 | 5.28 | 4.19 | 100 | SS2KPB | 1RA | LSF33 | 120.28 |
115 | M115 | 0.94 | 4" | 1.73 | 5" | 3.39 | 3.70 | 3.39 | 3.85 | 5.25 | 5.78 | 5.06 | 115 | SS2KPB | 1RA | LSF34 | 188.72 |
130 | M130 | 0.94 | 5" | 1.84 | - | 3.82 | 4.33 | 3.82 | 4.52 | 6.00 | 6.60 | 5.10 | 130 | SS2KPB | 1RA | LSF35 | 225.40 |
Dimensions displayed in inches unless otherwise stated |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Diameter over Lead Sheath 'A' | Overall Cable Diameter 'B' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
||||||||
Standard | Option | ||||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
20S16 | M20 | 15.0 | ½' | 19.9 | ¾" | 3.2 | 7.8 | 3.2 | 8.6 | 24.0 | 26.4 | 49.5 | 20S16 | SS2KPB | 1RA | PVC04 | 0.14 |
20S | M20 | 15.0 | ½' | 19.9 | ¾" | 6.1 | 11.0 | 6.1 | 11.7 | 24.0 | 26.4 | 49.5 | 20S | SS2KPB | 1RA | PVC04 | 0.13 |
20 | M20 | 15.0 | ½' | 19.9 | ¾" | 6.5 | 13.4 | 6.5 | 14.0 | 27.0 | 29.7 | 54.5 | 20 | SS2KPB | 1RA | PVC05 | 0.16 |
25 | M25 | 15.0 | ¾' | 20.2 | 1" | 11.1 | 19.3 | 11.1 | 20.0 | 36.0 | 39.6 | 66.5 | 25 | SS2KPB | 1RA | PVC09 | 0.30 |
32 | M32 | 15.0 | 1' | 25.0 | 1 ¼" | 17.0 | 25.5 | 17.0 | 26.3 | 41.0 | 45.1 | 67.5 | 32 | SS2KPB | 1RA | PVC10 | 0.36 |
40 | M40 | 15.0 | 1 ¼' | 25.6 | 1 ½" | 23.5 | 31.2 | 23.5 | 32.1 | 50.0 | 55.0 | 70.5 | 40 | SS2KPB | 1RA | PVC13 | 0.51 |
50S | M50 | 15.0 | 1 ½' | 26.1 | 2" | 31.0 | 37.2 | 31.0 | 38.2 | 55.0 | 60.5 | 65.5 | 50S | SS2KPB | 1RA | PVC15 | 0.57 |
50 | M50 | 15.0 | 2' | 26.9 | 2 ½" | 35.6 | 42.6 | 35.6 | 44.0 | 60.0 | 66.0 | 70.5 | 50 | SS2KPB | 1RA | PVC18 | 0.60 |
63S | M63 | 15.0 | 2' | 26.9 | 2 ½" | 41.5 | 48.5 | 41.5 | 49.9 | 70.5 | 77.6 | 70.5 | 63S | SS2KPB | 1RA | PVC21 | 0.90 |
63 | M63 | 15.0 | 2 ½' | 39.9 | 3" | 47.2 | 54.2 | 47.2 | 55.9 | 75.0 | 82.5 | 71.5 | 63 | SS2KPB | 1RA | PVC23 | 0.86 |
75S | M75 | 15.0 | 2 ½' | 39.9 | 3" | 54.0 | 60.2 | 54.0 | 61.9 | 80.0 | 88.0 | 70.5 | 75S | SS2KPB | 1RA | PVC25 | 1.03 |
75 | M75 | 15.0 | 3' | 41.5 | 3 ½" | 61.1 | 65.2 | 61.1 | 67.9 | 84.0 | 92.4 | 75.5 | 75 | SS2KPB | 1RA | PVC26 | 1.00 |
90 | M90 | 24.0 | 3 ½' | 42.8 | 4" | 66.6 | 77.1 | 66.6 | 79.4 | 108.0 | 118.8 | 113.5 | 90 | SS2KPB | 1RA | PVC31 | 3.01 |
100 | M100 | 24.0 | 3 ½' | 42.8 | 4" | 76.0 | 88.1 | 76.0 | 90.9 | 123.0 | 134.2 | 106.5 | 100 | SS2KPB | 1RA | LSF33 | 3.41 |
115 | M115 | 24.0 | 4" | 44.0 | 5" | 86.0 | 94.1 | 86.0 | 97.9 | 133.4 | 146.7 | 128.5 | 115 | SS2KPB | 1RA | LSF34 | 5.35 |
130 | M130 | 24.0 | 5" | 46.8 | - | 97.0 | 110.1 | 97.0 | 114.9 | 152.4 | 167.6 | 129.5 | 130 | SS2KPB | 1RA | LSF35 | 6.39 |
Dimensions displayed in millimeters unless otherwise stated |
Lead Covered / Lead Sheathed Cables
In addition to the standard requirements for SWA cables, there is a set of special guidelines for lead covered cables intended for direct burial in the ground of hydrocarbons processing and refinery sites. These guidelines were introduced in the UK by the Oil Companies Material Association (OCMA) and responsibility for these were subsequently transferred to EEMUA, the Engineering Equipment and Material Users Association.