RA2e | Ex eb, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Unarmoured & Braid Armour Cables
We'd like to keep in touch
We have some exciting things in the pipeline - if you'd like to be the first to know please enter your email address below.
Internationally Approved, Ex e, Explosive Atmosphere Cable Gland
• Supplied with face seal
• 10mm thread length on sizes 32 and below
• Displacement type flameproof seal
• Deluge protected
• -60°C to +130°C
• Internationally marked, IECEx & ATEX
Design Specification | BS 6121:Part 1:1989, IEC 62444, EN 62444 |
Mechanical Classifications* | Impact = Level 8, Retention = Class B |
Enclosure Protection | IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only |
ATEX Certificate | CML 18ATEX1321X, CML 18ATEX4313X |
Code of Protection | II 2G II 1D Ex eb IIC Gb, Ex ta IIIC Da II 3G Ex nR IIC Gc |
Compliance Standards | EN 60079-0,7,31 |
IECEx Certificate | IECEx CML 18.0179X |
Code of Protection | Ex eb IIC Gb, Ex ta IIIC Da, Ex nR IIC Gc |
Compliance Standards | IEC 60079-0,7,31 |
KCs Certificate | 13_GA4BO_0749X, 13_GA4BO_0750X, 14_GA4BO_0251X |
NEPSI Certificate | GYJ18.1249X |
CCOE / PESO (India) Certificate | Ex d: P548696, Ex e: P533772 Ex nR: P548695 |
Marine Approvals | LRS: 01/00172 (E3), DNV: TAE000000Y, ABS: 01-LD234401B/2-PDA |
Ingress Protection Rating ** | IP66, IP67 & IP68 |
Deluge Protection Compliance | DTS01 : 91 |
Cable Gland Material | Brass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium |
Seal Material | CMP SOLO LSF Halogen Free Thermoset Elastomer |
Cable Type | Unarmoured & Braided when terminated inside enclosure |
Sealing Technique | CMP Unique Displacement Seal Concept |
Sealing Area(s) | Cable Outer Sheath |
Optional Accessories | Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs |
Optional Installation Tools | Spanners |
* Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** Refer to Maintaining a Seal for further information on Ingress Protection Ratings
Certificates
Product Selection Table
Click here to view how to order
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Overall Cable Diameter 'A' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Ozs) |
|||||||
Standard | Option | ||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
16 | M16 | 0.39 | - | - | - | 0.13 | 0.34 | 1.06 | 1.17 | 1.16 | 16 | RA2E | 1RA | PVC02 | 2.12 |
20S16 | M20 | 0.39 | ½' | 19.9 | ¾' | 0.13 | 0.34 | 1.06 | 1.17 | 1.03 | 20S16 | RA2E | 1RA | PVC04 | 2.47 |
20S | M20 | 0.39 | ½' | 19.9 | ¾' | 0.24 | 0.46 | 1.06 | 1.17 | 1.02 | 20S | RA2E | 1RA | PVC04 | 2.12 |
20 | M20 | 0.39 | ½' | 19.9 | ¾' | 0.26 | 0.55 | 1.06 | 1.17 | 1.08 | 20 | RA2E | 1RA | PVC05 | 2.47 |
25 | M25 | 0.39 | ¾' | 20.2 | 1' | 0.44 | 0.79 | 1.42 | 1.56 | 1.41 | 25 | RA2E | 1RA | PVC09 | 4.59 |
32 | M32 | 0.39 | 1' | 25.0 | 1 ¼' | 0.67 | 1.04 | 1.61 | 1.78 | 1.40 | 32 | RA2E | 1RA | PVC10 | 5.29 |
40 | M40 | 0.59 | 1 ¼' | 25.6 | 1 ½' | 0.93 | 1.27 | 1.97 | 2.17 | 1.39 | 40 | RA2E | 1RA | PVC13 | 7.05 |
50S | M50 | 0.59 | 1 ½' | 26.1 | 2' | 1.22 | 1.50 | 2.36 | 2.60 | 1.33 | 50S | RA2E | 1RA | PVC15 | 9.17 |
50 | M50 | 0.59 | 2' | 26.9 | 2 ½' | 1.40 | 1.73 | 2.36 | 2.60 | 1.48 | 50 | RA2E | 1RA | PVC18 | 9.52 |
63S | M63 | 0.59 | 2' | 26.9 | 2 ½' | 1.63 | 1.96 | 2.95 | 3.25 | 1.37 | 63S | RA2E | 1RA | PVC21 | 15.17 |
63 | M63 | 0.59 | 2 ½' | 39.9 | 3' | 1.86 | 2.20 | 2.95 | 3.25 | 1.46 | 63 | RA2E | 1RA | PVC23 | 14.11 |
75S | M75 | 0.59 | 2 ½' | 39.9 | 3' | 2.13 | 2.44 | 3.54 | 3.90 | 1.37 | 75S | RA2E | 1RA | PVC24 | 18.34 |
75 | M75 | 0.59 | 3' | 41.5 | 3 ½' | 2.41 | 2.67 | 3.50 | 3.85 | 1.60 | 75 | RA2E | 1RA | PVC26 | 17.64 |
90 | M90 | 0.94 | 3 ½' | 42.8 | 4' | 2.62 | 3.15 | 4.25 | 4.68 | 2.37 | 90 | RA2E | 1RA | PVC31 | 56.44 |
100 | M100 | 0.94 | 3 ½' | 42.8 | 4' | 2.99 | 3.58 | 4.84 | 5.33 | 2.14 | 100 | RA2E | 1RA | LSF33 | 62.79 |
115 | M115 | 0.94 | 4' | 44.0 | 5' | 3.39 | 3.85 | 5.25 | 5.78 | 2.61 | 115 | RA2E | 1RA | LSF34 | 94.18 |
130 | M130 | 0.94 | 5' | 46.8 | - | 3.82 | 4.52 | 6.00 | 6.60 | 2.94 | 130 | RA2E | 1RA | LSF35 | 134.04 |
Cable Gland Size | Available Entry Threads 'C' (Alternate Metric Thread Lengths Available) | Overall Cable Diameter 'A' | Across Flats 'D' | Across Corners 'D' | Protrusion Length 'F' | Combined Ordering Reference (*Brass Metric) | Shroud | Cable Gland Weight (Kgs) |
|||||||
Standard | Option | ||||||||||||||
Metric | Thread Length (Metric) 'E' | NPT | Thread Length (NPT) 'E' | NPT | Min | Max | Max | Max | Size | Type | Ordering Suffix |
||||
16 | M16 | 10.0 | - | - | - | 3.2 | 8.7 | 27.0 | 29.7 | 29.4 | 16 | RA2E | 1RA | PVC02 | 0.06 |
20S16 | M20 | 10.0 | ½' | 19.9 | ¾' | 3.2 | 8.7 | 27.0 | 29.7 | 26.2 | 20S16 | RA2E | 1RA | PVC04 | 0.07 |
20S | M20 | 10.0 | ½' | 19.9 | ¾' | 6.1 | 11.7 | 27.0 | 29.7 | 25.9 | 20S | RA2E | 1RA | PVC04 | 0.06 |
20 | M20 | 10.0 | ½' | 19.9 | ¾' | 6.5 | 14.0 | 27.0 | 29.7 | 27.4 | 20 | RA2E | 1RA | PVC05 | 0.07 |
25 | M25 | 10.0 | ¾' | 20.2 | 1' | 11.1 | 20.0 | 36.0 | 39.6 | 35.9 | 25 | RA2E | 1RA | PVC09 | 0.13 |
32 | M32 | 10.0 | 1' | 25.0 | 1 ¼' | 17.0 | 26.3 | 41.0 | 45.1 | 35.5 | 32 | RA2E | 1RA | PVC10 | 0.15 |
40 | M40 | 15.0 | 1 ¼' | 25.6 | 1 ½' | 23.5 | 32.2 | 50.0 | 55.0 | 35.2 | 40 | RA2E | 1RA | PVC13 | 0.20 |
50S | M50 | 15.0 | 1 ½' | 26.1 | 2' | 31.0 | 38.2 | 60.0 | 66.0 | 33.9 | 50S | RA2E | 1RA | PVC15 | 0.26 |
50 | M50 | 15.0 | 2' | 26.9 | 2 ½' | 35.6 | 44.0 | 60.0 | 66.0 | 37.5 | 50 | RA2E | 1RA | PVC18 | 0.27 |
63S | M63 | 15.0 | 2' | 26.9 | 2 ½' | 41.5 | 49.9 | 75.0 | 82.5 | 34.7 | 63S | RA2E | 1RA | PVC21 | 0.43 |
63 | M63 | 15.0 | 2 ½' | 39.9 | 3' | 47.2 | 55.9 | 75.0 | 82.5 | 37.0 | 63 | RA2E | 1RA | PVC23 | 0.40 |
75S | M75 | 15.0 | 2 ½' | 39.9 | 3' | 54.0 | 61.9 | 90.0 | 99.0 | 34.7 | 75S | RA2E | 1RA | PVC24 | 0.52 |
75 | M75 | 15.0 | 3' | 41.5 | 3 ½' | 61.1 | 67.9 | 89.0 | 97.9 | 40.6 | 75 | RA2E | 1RA | PVC26 | 0.50 |
90 | M90 | 24.0 | 3 ½' | 42.8 | 4' | 66.6 | 79.9 | 108.0 | 118.8 | 60.3 | 90 | RA2E | 1RA | PVC31 | 1.60 |
100 | M100 | 24.0 | 3 ½' | 42.8 | 4' | 76.0 | 91.0 | 123.0 | 135.3 | 54.3 | 100 | RA2E | 1RA | LSF33 | 1.78 |
115 | M115 | 24.0 | 4' | 44.0 | 5' | 86.0 | 97.9 | 133.4 | 146.7 | 66.2 | 115 | RA2E | 1RA | LSF34 | 2.67 |
130 | M130 | 24.0 | 5' | 46.8 | - | 97.0 | 114.9 | 152.4 | 167.6 | 74.8 | 130 | RA2E | 1RA | LSF35 | 3.80 |
Dimensions displayed in millimeters unless otherwise stated |
NORSOK Standard I-001 – Field Instrumentation
The current NORSOK standard I-001 includes the following requirements related to cables and cable glands. We recommend that users consult the whole of the I-001 standard, and note that the following are selected extracts that may have an effect on the use of our products.
Read moreTypical IEC / NORSOK Selection Comparisons
The illustrations shown on the cable entries Type 'd' & cable entries Type 'e' highlight the main differences when it comes to selecting cable glands for IEC and NORSOK installations. The combinations of enclosure and cable gland types featured in these illustrations apply when either braided or unarmoured cables are used. It is assumed that for installations complying with Norsok requirements that cables are in accordance with NEK TS 606 and installations comply with IEC 60092 / IEC 61892 and that for other IEC installations the cable complies with 9.3.2(a) of IEC 60079-14:2013. The illustrations also assume that for Flameproof type ‘d’ (Ex d) enclosures the installed cable is at least 3 metres long and the cable gland itself is not approved as part of the equipment.
Read moreSupporting and Security of Cables
The content of clauses 9.9.1 & 9.9.2 explains the technique to be adopted for preparation and termination of cables. Please note that this information is not meant to reflect the NORSOK standards in their entirety, but only to demonstrate the cable sealing and termination of wire braid in the cables. Users are required to digest and fully understand the NORSOK standards and should not use the context of the partial information provided as the basis of their decision making.
Read moreVisit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.
Sign up now