Triton CDS PB (T3CDSPB) | Ex eb, Ex db, Ex nR, Ex ta | Explosive Atmosphere Cable Gland For all types of Lead Sheathed Armoured Cables

Globally Approved, Explosive Atmosphere Cable Gland

• Effectively earths / grounds lead sheathed cables
• Fully sequential, three step installation procedure
• Direct & remote installation
• Unique compensating displacement seal system (CDS)
– Metal-to-metal installation every time regardless of lead sheath diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX, UL & cCSAus
• Superior EMC Performance

† Grooved Cone (X) is predominantly used for Wire Braid (e.g. GSWB, TCWB), Steel Tape Armour (STA, DSTA) and Aluminium Strip Armour (ASA) but is also suitable for Single Wire Armour (SWA), Aluminium Wire Armour (AWA) and Pliable Wire Armour (PWA) if the range is outside that of the Stepped Cone (W).

Note: Grooved Cone (X) dimensions shown in the Cable Gland Selection Table below are for a double wire strand of braid armour cables. Tapes can also be doubled over. For cables that have only a single layer of armour such as SWA the clamping range should be used as shown in the table below. Stepped (W) Cone is suitable for Single Wire Armour (SWA), or Aluminium Wire Armour (AWA) cables.

For under / oversized armour wires click here

Patents granted: DE 1077517, FR 1077517, GB 1077517

Design Specification BS 6121:Part 1:1989, IEC 62444, EN 62444
Mechanical Classifications* Impact = Level 8, Retention = Class D
Enclosure Protection IK10 to IEC 62262 (20 joules) Brass & Stainless Steel only
Electrical Classifications * Category B (Category A when used with braid, tape or pliable wire armour cables)
ATEX Certificate CML 18ATEX1326X
CML 18ATEX4318X
UKEX Certificate "CML 21UKEX1258X,CML 21UKEX4259X"
Code of Protection II 2G, II 1D, Ex db IIC Gb, Ex eb IIC Gb, Ex ta IIIC Da,
II 3G Ex nR IIC Gc, I M2, Ex db I Mb, Ex eb I Mb
Compliance Standards EN60079-0,1,7,15,31
IECEx Certificate IECEx CML 18.0183X
Code of Protection Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex ta IIIC Da, Ex db I Mb, Ex eb I Mb
Compliance Standards IEC 60079-0,1,7,15,31
ECAS Certificate 20-02-05626
EAC Certificate C-GB.AД07.B.04599/22
CCC Certificate 2020322313002527
CCOE / PESO (India) Certificate Ex d: P548696, Ex e: P533772 Ex nR: P548695
INMETRO Certificate TÜV 11.0374X
RETIE Certificate 03866
UkrSEPRO CU 19.0371X
Marine Approvals LRS: 01/00172 (E3), DNV: TAE00000Y, ABS: 20-LD1948801-PDA, BV: 43180/A1BV
Ingress Protection Rating ** IP66, IP67 & IP68
Deluge Protection Compliance DTS01 : 91
Cable Gland Material Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel
Seal Material CMP SOLO LSF Halogen Free Thermoset Elastomer
Cable Type Lead Sheathed & Single Wire Armour (LC/SWA), Lead Sheathed & Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour (LC/SWB), Lead Sheathed & Pliable Wire Armour (LC/PWA), Lead Sheathed & Steel Tape Armour (LC/STA), Lead Sheathed & Aluminium Strip Armour (LC/ASA)
Armour Clamping Reversible Armour Cone & AnyWay Universal Clamping Ring
Sealing Technique Inner Bedding Sealing Ring: Compensating Displacement Seal (CDS), Outer Sheath Sealing Ring : Load Retention Seal (LRS)
Sealing Area(s) Cable Inner Bedding & Outer Cable Sheath
Optional Accessories Locknuts, Earth Tags, Serrated Washers, Entry Thread Seals, Shrouds,Ingress Discs
Optional Installation Tools Spanners

Note: * Mechanical & Electrical Classifications applied as per IEC 62444 & EN 62444
** When CMP installation accessories are used. Refer to Maintaining a Seal for further information.
*** IP68 tested to a minimum depth of 30 metres for 12 hours, alternate depths / durations can be provided upon request

Jump to technical illustration   

Certificates

Click here to view Certificates

Product Selection Table

Click here to view how to order

Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Lead Sheath Diameter 'A'Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M200.59½'0.78¾"0.120.310.240.520.010.040.030.050.941.043.1020S16T3CDSPB1RAPVC367.05
20SM200.59½'0.78¾"0.240.430.370.630.010.040.030.050.941.043.1020ST3CDSPB1RAPVC367.05
20M200.59½'0.78¾"0.260.530.490.820.020.040.030.051.201.323.0020T3CDSPB1RAPVC069.88
25SM250.59¾'0.801"0.440.760.550.870.020.050.050.061.481.633.5025ST3CDSPB1RAPVC0915.52
25M250.59¾'0.801"0.440.760.721.030.020.050.050.061.481.633.4925T3CDSPB1RAPVC0915.52
32M320.591'0.981 ¼"0.671.000.931.330.020.050.060.081.811.993.5732T3CDSPB1RAPVC1122.58
40M400.591 ¼'1.011 ½"0.871.231.101.590.020.060.060.082.172.383.6740T3CDSPB1RAPVC1532.10
50SM500.591 ½'1.032"1.161.461.391.840.020.060.080.102.362.603.9650ST3CDSPB1RAPVC1839.86
50M500.592'1.062 ½"1.401.681.592.090.020.060.080.102.763.044.1750T3CDSPB1RAPVC2156.79
63SM630.592'1.062 ½"1.581.911.802.340.020.060.080.102.953.254.0463ST3CDSPB1RAPVC2361.38
63M630.592 ½'1.573"1.862.132.152.590.020.060.080.103.153.464.1563T3CDSPB1RAPVC2563.14
75SM750.592 ½'1.573"2.082.372.322.830.020.060.080.103.543.904.3575ST3CDSPB1RAPVC2891.01
75M750.593'1.633 ½"2.332.572.633.090.020.060.100.123.944.334.7475T3CDSPB1RAPVC30117.82
90M900.943 ½'1.694"2.623.043.003.560.030.060.120.164.534.985.4790T3CDSPB1RAPVC32172.49
100M1000.943 ½'1.694"2.993.473.393.990.030.060.120.165.005.505.05100T3CDSPB1RALSF33176.02
115M1150.944"1.735"3.393.704.004.340.030.060.120.165.435.986.35115T3CDSPB1RALSF34273.37
130M1300.945"1.84-3.824.334.344.850.030.060.120.166.186.806.82130T3CDSPB1RALSF35346.04
Dimensions are displayed in inches unless otherwise stated
Cable Gland SizeAvailable Entry Threads 'C' (Alternate Metric Thread Lengths Available)Lead Sheath Diameter 'A'Overall
Cable
Diameter
'B'
Armour RangeAcross
Flats
'D'
Across
Corners
'D'
Protrusion
Length 'F'
Combined Ordering Reference
(*Brass Metric)
ShroudCable
Gland
Weight
(Kgs)
StandardOptionGrooved
Cone (X)
Stepped Cone (W)
MetricThread Length (Metric) 'E'NPTThread Length
(NPT) 'E'
NPTMinMaxMinMaxMinMaxMinMaxMaxMaxSizeTypeOrdering
Suffix
20S16M2015.0½'19.9¾"3.17.86.113.10.31.00.81.2524.026.478.720S16T3CDSPB1RAPVC360.20
20SM2015.0½'19.9¾"6.111.09.515.90.31.00.81.2524.026.478.720ST3CDSPB1RAPVC360.20
20M2015.0½'19.9¾"6.513.412.520.90.41.00.81.2530.533.676.220T3CDSPB1RAPVC060.28
25SM2515.0¾'20.21"11.119.314.022.00.41.21.31.637.541.388.825ST3CDSPB1RAPVC090.44
25M2515.0¾'20.21"11.119.318.226.20.41.21.31.637.541.388.725T3CDSPB1RAPVC090.44
32M3215.01'25.01 ¼"17.025.523.733.90.41.21.62.046.050.690.732T3CDSPB1RAPVC110.64
40M4015.01 ¼'25.61 ½"22.031.227.940.40.41.61.62.055.060.593.240T3CDSPB1RAPVC150.91
50SM5015.01 ½'26.12"29.537.235.246.70.41.62.02.560.066.0100.750ST3CDSPB1RAPVC181.13
50M5015.02'26.92 ½"35.642.640.453.00.61.62.02.570.177.1105.850T3CDSPB1RAPVC211.61
63SM6315.02'26.92 ½"40.148.545.659.40.61.62.02.575.082.5102.563ST3CDSPB1RAPVC231.74
63M6315.02 ½'39.93"47.254.254.665.80.61.62.02.580.088.0105.463T3CDSPB1RAPVC251.79
75SM7515.02 ½'39.93"52.860.259.072.00.61.62.02.590.099.0110.675ST3CDSPB1RAPVC282.58
75M7515.03'41.53 ½"59.165.266.778.40.61.62.53.0100.0110.0120.375T3CDSPB1RAPVC303.34
90M9024.03 ½'42.84"66.677.176.290.30.81.63.24.0115.0126.5138.990T3CDSPB1RAPVC324.89
100M10024.03 ½'42.84"76.088.186.1101.40.81.63.24.0127.0139.7128.2100T3CDSPB1RALSF334.99
115M11524.04"44.05"86.094.1101.5110.20.81.63.24.0138.0151.8161.3115T3CDSPB1RALSF347.75
130M13024.05"46.8-97.0110.1110.2123.20.81.63.24.0157.0172.7173.3130T3CDSPB1RALSF359.81
Dimensions are displayed in millimetres unless otherwise stated

Technical Illustration

Additional Information

ATEX Responsibilities

When placing cable glands or similar equipment on the market, manufacturers should provide a Declaration of Conformity confirming that its products are identical to the samples originally type tested by the Ex Notified body, and that they meet the Essential Health & Safety Requirements of the Directive 2014/34/EU.

Read more

The Galvanic Series

A set of values has been given to a series of metals and alloys in terms of their relative nobility, or ability to resist corrosion, whilst immersed in sea water. In other situations, where materials are not immersed, but are exposed to atmospheric contaminants, their status will be largely dependent upon the environment in which they are located.

Read more

Lead Covered / Lead Sheathed Cables

In addition to the standard requirements for SWA cables, there is a set of special guidelines for lead covered cables intended for direct burial in the ground of hydrocarbons processing and refinery sites. These guidelines were introduced in the UK by the Oil Companies Material Association (OCMA) and responsibility for these were subsequently transferred to EEMUA, the Engineering Equipment and Material Users Association.

Read more

Visit our Knowledge Base for technical expertise and advice, gathered over CMP's 60+ years' experience in the art of terminating cable glands.

Sign up now